Air cooled chiller 50-179 kw

The CHA/IK/A 172-P÷574-P series of chillers and heat pumps with R410A refrigerant gas are designed to meet the cooling needs of medium-sized service sector or manufacturing areas. 

Even in the super silent versions, they are equipped with axial fans, inverter scroll compressors and plate heat exchangers. 

All units have class A energy efficiency and are equipped with inverter control on the Scroll compressor to ensure higher efficiency at partial loads (SEER/IPLV/SCOP).  Chillers with microchannel condensing coils provide high efficiency (high EER) due to better heat exchange than traditional coil chillers. There is also inverter control on the circulation pump and fans (EC Inverter) to further increase efficiency. A wide range of accessories, either factory-installed or supplied separately, complete the series' outstanding versatility and functionality.

The Heat Pump versions are designed for hot water production up to 55°C. 

The units comply with the ErP Regulation. On request, the units can be equipped with R452B or R454B refrigerant gas.   


Features
  • Polyester powder coated, corrosion resistant supporting frame construction 
  • Inverter DC Scroll Compressor with oil sight glass, internal heat protection, crankcase heater and soundproofing cover
  • Axial fans directly connected to external rotor motors
  • Condenser made of copper tube and aluminum finned coils or aluminum microchannel coils
  • 172-P÷372-P models with AISI 316 stainless steel welded plates with one circuit on the refrigerant side and one on the water side; 484-P÷574-P models with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch. Heat Pump units have an antifreeze heater
  • Electronic expansion valve
  • R410A refrigerant gas, optionally R452B or R454B refrigerant
  • Microprocessor control and regulation system

Technical specifications
 

172-P192-P212-P232-P272-P302-P352-P372-P484-P574-P
Cooling STD versionsCooling capacity (1)kW49,957,765,774,885,997,7112130152179
Pulling force (1)kW15,618,120,423,627,030,335,040,547,255,6
EER (1)
3,203,193,223,173,183,223,203,213,223,22
Cooling STD versions (EN14511)Cooling capacity (1)kW49,657,465,474,485,497,2112129151178
Pulling force (1)kW15,918,420,724,027,530,835,641,147,856,2
EER (1)
3,123,123,163,103,113,163,153,143,163,17
SEER (2)
4,414,554,414,394,424,434,494,394,404,34
Energy efficiency (2)%173179173173174174177173173171
Cooling MC versionsCooling capacity (1)kW49,957,765,774,885,997,7112130152179
Pulling force (1)kW15,417,920,223,426,730,034,740,146,755,0
EER (1)
3,243,223,253,203,223,263,233,243,253,25
Soyutma MC versiyaları (EN14511)Cooling capacity (1)kW49,657,465,474,485,497,2112129151178
Pulling force (1)kW15,718,220,523,827,230,535,240,747,355,6
EER (1)
3,163,153,193,133,143,193,183,173,193,20
SEER (2)
4,454,604,454,434,464,474,534,434,444,38
Energy efficiency (2)%175181175174175176178174175172
Heating STD versionsHeating power (3)kW53,762,271,080,792,6105121140164193
Pulling force (3)kW16,218,721,224,528,031,436,441,849,057,7
COP (3)
3,313,333,353,293,313,343,323,353,353,34
Heating STD versions (EN14511)Heating power (3)kW54,162,671,481,293,2106122141165194
Pulling force (3)kW16,619,221,625,128,832,237,243,050,058,8
COP (3)
3,263,263,313,243,243,303,283,273,303,30
SCOP (4)
3,473,433,423,583,603,463,523,493,443,43
Energy efficiency (4)%136134134140141135138137135134
Energy class (5)
A+A+A+A+------
CompressorQuantity
2222222244
Refrigerant circuits1111111122
Power steps
SteplessSteplessSteplessSteplessSteplessSteplessSteplessSteplessSteplessStepless
EvaporatorWater flow rate
l/s2,382,763,143,574,104,675,356,217,268,55
Pressure losses
kPa41403239474035443330
Water connections
"G1 ½"1 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"
Electrical characteristicsPower source
V/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. operating currentA4545545463698989112129
Max.initial starting currentA128128176176187237230230245297
Pumped devicesPump's available static pressurekPa140135140125130180175160160145
Water connections"G2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"
ECH fan available static pressureSTD versiyalarıPa706010080758080807565
SSL versionsPa7060959080808080------
MC versionsPa60659580807575757575
MC/SSL versionsPa6065958080757575------
Səs səviyyəsiSTD versions (6)dB(A)63656666676868696868
STD versions with SL accessory (6)dB(A)61626464656666676666
SSL versions (6)dB(A)5860616162626263------
MC versions (6)dB(A)62646565666767686767
MC versions with SL accessory (6)dB(A)60616363646565666565
MC/SSL versions (6)dB(A)5759606061616162------
Weight STD versionsShipping weight
kg6146887477567658571086109514491494
Working weightkg6206957557657758701100111014701520

Dimensions
 

172-P192-P212-P232-P272-P302-P352-P372-P484-P574-P
LengthSTD-MCmm2350235023502350235035503550355047004700
SSL-MC/SSLmm23502350235035503550355047004700------
WidthSTD-SSL-MC-MC/SSLmm1100110011001100110011001100110011001100
HeightSTD-MCmm1920222022202220222019202220222022202220
SSL-MC/SSLmm19202220222019201920222022202220------


Notes

1. Chilled water between 12 and 7 °C, ambient air temperature 35 °C.
2. Seasonal energy efficiency of low temperature cooling. According to EU Regulation n. 2016/2281.
3.  Water heated between 40 and 45 °C, ambient air temperature 7 °C d.c./6 °C a.c.
4.  Seasonal energy efficiency of heating at low temperatures with average climate conditions. According to EU Regulation n. 813/2013.
5.  Seasonal energy efficiency class for low-temperature heating under average climate conditions. According to EU Regulation n. 811/2013.
6.  Sound pressure level measured at a distance of 1 m from the device in free field conditions. According to ISO 3744.